Low Light Imaging Cameras

iXonEM+ EMCCD Camera

Blue

Andor’s iXonEM Blue back-illuminated EMCCD has single photon detection capability combined with exceptional QE performance in the blue wavelength region. Part of the acclaimed iXonEM+ platform, Blue is designed to extract the absolute best from quantitative EMCCD technology across all critical performance parameters, in addition offering greater than 20% extra QE response to blue photons (compared to the ‘standard’ back-illuminated QE curve).

Technical Specifications

  • What does this specification mean?Active Pixels

    512 x 512

  • Pixel Size (µm)

    16

  • Image Area

    8.2mm x 8.2mm

  • What does this specification mean? Act. Area Pixel Well Depth (e-, typical)

    160000
    Maximum: 220000

  • Gain Reg. Pix. Well Depth (e-, typical)

    800000

  • Max Readout Rate

    10MHz

  • What does this specification mean? Frame Rate (fps)

    35

  • Read Noise (e-, typical)

    < 1 to 49 @ 10 MHz

Features and Benefits

  • Extra QE response in the blue

    Compared to the ‘standard’ back-illuminated QE curve, iXonEM Blue offers enhanced QE between 300nm to 470nm (70% @ 380nm).

  • EMCCD Technology

    Even single photon signals are amplified above the noise floor. Full QE of CCD chip is harnessed (no intensifier).

  • TE Cooling to -100°C

    Critical for elimination of darkcurrent detection limit.

  • RealGain™

    Absolute EMCCD gain selectable directly from a linear and quantitative scale.

  • EMCAL™

    Innovative user-initiated self-recalibration of EM Gain.

  • iCam

    Unique innovation that empowers the Clara to operate with market-leading acquisition efficiency through live cell microscopy software

  • UltraVac™

    Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance, year after year.

  • Variable Readout Rates Up To 10 MHz

    Quantitative accuracy at all speeds. Slower readout rate for enhanced 16-bit dynamic range.

  • Selectable amplifier outputs– EMCCD & conventional

    Highly flexible camera optimized for both fast, ultra lowlight imaging and ‘bright-field’ or conventional fluorescence imaging.

  • High dynamic range & 16-bit digitization available

    Extended sensor dynamic range (readout speed dependent) and matched digitization for quantization of dim and bright signals.

  • Minimal Clock-Induced Charge

    Giving lowest “spurious noise” specification; essential for single photon counting.

  • Cropped Sensor Mode

    Specialized readout mode for achieving sub-millisecond temporal resolution from EMCCD and CCD cameras. Intuitive Cropped Sensor definition for continuous rapid image or spectral acquisition.

  • Enhanced Baseline Clamp

    Essential for quantitative accuracy of dynamic measurements.

  • Built-in C-mount Compatible Shutter

    Easy means to record control dark images - excellent for optimization of experimental set-up.

Quantum Efficiency Curve

QE Data114

Build System

Controller Cards

You will require one of these options to operate this camera

Software

You will require one of these options to operate this camera

  • 3rd Party Software CompatibilityDrivers are available so the camera can operate through popular third party imaging software packages. Please contact us for a list of to see if you software is compatible Add to wishlist

  • iQThe best live cell imaging software just got betterAdd to wishlist

  • SDKAndor Software Development Kit (SDK)Add to wishlist

  • Solis (I)Solis-I for Imaging CamerasAdd to wishlist

Cooling Options

  • XW-CHIL-150Ultra compact chiller unit for ultimate cooling performanceAdd to wishlist

  • XW-RECRRe-circulator for enhanced cooling performanceAdd to wishlist

Mouse Eye Tracking by PicNet Software Development Services